he properties of product structure and composition of the components of A "platinum catalyst for the structure of the structure, part B for vinyl inception. This product is made of liquid materials and powder. Main raw materials are wt, silicon resin, calcium carbonate and quartz powder.The specifications and traits] : KaiMeng mould material including hydrophilic putty (0), hydrophilic high viscosity (1), (2) medium viscosity hydrophilic type) and hydrophilic low viscosity (3).Hydrophilic putty (0) : specification is 400g 2 x, As the material, also can be used to held the occlusive recording materialsPut putty
More than 60 secondsIn curing time
Five minutesA group of into white be bored with childGroup B into reddish-brown putty
Hydrophilic high viscosity (1) specifications for 2 x 25ml, Can inject mould material dentalIn time
More than 40 secondsIn curing time
Five minutesA group of into white pasteGroup B into cui blue paste
Hydrophilic medium viscosity (2) : specification for 2 x 25ml, Can inject mould material dentalIn time
More than 40 secondsIn curing time
Five minutesA group of into white pasteGroup B into cui blue paste
Hydrophilic low viscosity (3) : specification for 2 x 25ml, Can inject mould material dentalIn time
More than 40 secondsIn curing time
Five minutesA group of into white pasteGroup B into cui blue paste
The scope of ": this product for making accurate crown and bridge, denture and bite records and oral organization mode by taking.[usage] this product can be used separately, Hydrophilic putty and injected materials (type 1 and type 2 or 3) can also be used mixed method, namely step. Use the following steps:1.the preparation and selecting or high enough hard wall, it can provide held that held the teeth form 2-3mm thickness mould material.2 in the thin coat held that held the binder and drying (at least 5 minutes). Segregation of teeth and place row gingiva line.3 will inject (type 1 and type 2 or 3) stamping materials directly into the mould injection of cylinder or to choose our company provide mouth injected head on mixing tube with direct injection. (note: with proper pressure injection in the mouth will head a blunt tip into mixing tube. In the first card into fixed injection can be heard, train-track clatters).4 equal amounts of hydrophilic putty A and part B separately.5. Remove gum line at the same time, immediately be injected mould material along the clean, dry teeth, assistant will inject hydrophilic putty A part A and part B mixed with finger to the uniform color (30 seconds), blending into the material with good adhesive, relative to held the position of the mould pressing took A concave (about 3 tooth size), with injected materials (type 1 and type 2 or 3) fill this sag.6 slowly with no hardening hydrophilic putty mixed but put inside the entrance of tray, let not the injection mould hardened type material in the teeth. Note: held in injection mould to type material (type 1 and type 2 or 3) mouth injected began to 60 seconds and hydrophilic putty mixed type for 60 seconds.7 will held in his mouth and not excessive fixed pressure seal completely hardening modulus materials until 5 minutes.8. Hardened, to press, held around the excessive use of pressure will not held out.9. Examine whether the defective or stamping die, torn, gingival ditch and dentition die materials are around.10. The die immediately with water rinse and dry.11 will die in the standard disinfection disinfectant immerses disinfection time in accordance with the manufacturer, to get the best advice. Remove mould, clean water and dry. Disinfection process does not affect the mould.12 after two hours after the hardening modulus, filling mold filling can use 3 and 4 type dental materials, the company of plaster mould material is very stable in two weeks, still can fill.13. The die must avoid deformation and pollution in the packing.
Take two steps of its basic procedures with the method of using hybrid step: (ChuYin hydrophilic putty) impression material take good first impression thoroughly clean, dry, the hydrophilic injected materials (type 1 and type 2 or 3) in the ChuYin silicone has molding mould tray, in the mouth bite from the mouth, hardened die out.Silicone rubber seal surface coating copper mould can or silver.
The product performance.Chemical properties: vinyl inceptionManual harmonic time: 30 seconds (23 degrees Celsius) working environment,Manual operation time: 90 seconds (23 degrees Celsius) working environment,Since the mouth in time: 5 minutesLargest compression deformation: < 1.0%, Deformation recovery rate: > 99.0%The maximum volume change: 24 hours < 0.3, 336 (two weeks) < 0.3 percentThe compressive deformation: 3.0% : 1.0-0), 2.0-6.0% (type 1 and type 2, 3)Suggestion: time to mold filling gypsum 2 hours - 2 weeks[contraindications] to impression materials have allergy history banned[note].1 temperature has significant effect on curing time under low temperature, curing speed is slow, high temperature, curing speed according to the environment and the operation temperature adjustment pace fingers.2 this product contains platinum